Gas to Electric Cooker Conversion London | £200 Fixed | Same Day
Home › Gas to Electric Cooker Conversion London
Gas Safe + Certified Electricians — London

Gas to Electric Cooker Conversion London — £200 Fixed

Complete gas to electric cooker conversion in London — £200 fixed price. Gas Safe disconnection of your old gas cooker, new dedicated cooker circuit installed and new electric cooker connected — all in one visit. Free electrical safety certificate. Old cooker removal £25 add-on. No call-out fee. Same day available.

£200
Complete conversion
1 visit
Everything done
Free
Electrical certificate
Same day
Available London
Gas Safe + Certified Engineers
£200 Fixed — All London Areas
Gas Disconnection + New Circuit + Installation
Free Electrical Certificate
Old Cooker Removal — £25
No Call-Out Fee · Same Day

Gas to electric cooker conversion in London — £200 fixed, one visit, everything included

Switching from a gas cooker to an electric cooker in London involves three separate jobs — gas disconnection, new cooker circuit installation and electric cooker connection. Most London homeowners do not realise this and end up booking multiple different engineers on different days. We handle all three in a single visit for £200 fixed — no callbacks, no coordination, no surprises.

Our team covers both Gas Safe gas disconnection and Part P certified electrical installation — making us one of the few services in London that can legally complete every step of a gas to electric conversion in one appointment.

Why does gas to electric conversion require 3 separate jobs?

This is the most common question we get from London homeowners considering switching. Here is why three jobs are involved:

  • Job 1 — Gas Safe disconnection: Under the Gas Safety (Installation and Use) Regulations 1998, disconnecting a gas appliance must be carried out by a Gas Safe registered engineer. This is a legal requirement — not optional.
  • Job 2 — New 32-amp cooker circuit: The vast majority of London properties that have only ever had a gas cooker will not have a dedicated electric cooker circuit. A new 32-amp circuit must be run from the fuse board to the cooker location before any electric cooker can be safely connected. This must be done by a Part P certified electrician.
  • Job 3 — Electric cooker installation: Once the circuit is in place, the new electric cooker is connected, levelled, tested and an electrical safety certificate issued.

We do all three — £200 total, one visit, price confirmed at booking.

Do most London properties need a new cooker circuit?

Yes — in almost all cases where a gas cooker is being replaced by an electric cooker for the first time. London properties built before 2000 — which includes the vast majority of Victorian terraces, Edwardian semis, 1930s semis and most purpose-built flat blocks — were built without a dedicated electric cooker circuit. The kitchen is wired for gas only. A new 32-amp dedicated circuit must be installed from the consumer unit (fuse board) to the cooker location. This is included in the £200 conversion price.

What happens to the gas pipe when switching from gas to electric in London?

When our Gas Safe engineer disconnects your gas cooker, the gas supply to the cooker location is safely capped off. The gas pipe or bayonet fitting at the wall is sealed so no gas can escape. The capped pipe does not need to be removed — it can remain in place behind the new electric cooker. Your gas supply to your boiler, any gas hob (if separate), and all other gas appliances in your property remains completely unaffected.

Gas to induction cooker conversion in London

We also carry out gas to induction cooker conversions in London at the same £200 fixed price. Induction cookers require exactly the same dedicated 32-amp or 45-amp circuit as a conventional electric cooker. The process is identical — gas disconnection, new circuit, induction cooker installation and free electrical safety certificate — all in one visit. Induction cookers are becoming increasingly popular in London kitchens due to their faster heating, lower energy consumption and improved safety compared to both gas and conventional electric.

Gas to electric conversion for London landlords

London landlords switching rental properties from gas to electric cookers need to ensure the entire process — gas disconnection, new circuit and electric installation — is carried out by qualified engineers and documented correctly. Our team provides a Gas Safe disconnection record and a Part P electrical installation certificate on every conversion. Both documents are required for landlord compliance records. We work with individual landlords, letting agents and property management companies across all London boroughs with same day availability for urgent property turnarounds.

What is included — £200

Complete gas to electric conversion — what the £200 covers

Three jobs. One visit. One fixed price. Confirmed before we start.

01
Gas Safe disconnection
Included in £200
Gas Safe registered engineer safely disconnects your existing gas cooker from the gas supply. Bayonet fitting or gas pipe at the wall is securely capped. Gas Safe disconnection record provided. Your boiler and all other gas appliances remain completely unaffected.
02
New 32-amp cooker circuit
Included in £200
New dedicated 32-amp cooker circuit run from your consumer unit (fuse board) to the cooker location. Required in virtually all London properties switching from gas to electric for the first time. Part P certified installation. All cable concealed where possible.
03
Electric cooker installation
Included in £200
New electric cooker connected to the new 32-amp circuit, levelled and positioned. All elements, oven, grill and controls tested and confirmed working. Free electrical safety certificate issued same day. 12-month workmanship guarantee.
Complete conversion — London
Gas to electric cooker conversion — everything in one visit
£200
Fixed price · All London areas · No call-out fee · No hidden charges
Gas Safe disconnection included
New 32-amp circuit included
Electric cooker installation included
Electrical safety certificate — free
Gas disconnection record included
12-month workmanship guarantee
No call-out fee
Same day available
Add-on services

Optional add-ons — book with conversion

🗑️
Old cooker removal
£25
Safe removal and disposal of your old gas cooker. Book with conversion for one visit total. Taken away — no skips or extra trips needed.
45-amp circuit upgrade
+£25
For electric range cookers over 7.2kW, a 45-amp circuit is required instead of 32-amp. Add £25 to the conversion price — total £225.
🏠
Cooker hood installation
From £80
Visor, chimney or built-in cooker hood installed in the same visit as your conversion. Visor from £80, chimney from £100, built-in from £120.
NOT included — old cooker removal
Physical removal and disposal of your old gas cooker is a separate £25 add-on. The £200 conversion price covers disconnection and all installation work. Tell us at booking if you need removal — we confirm your total.
📋
Free electrical safety certificate — every conversion
Part P compliant electrical safety certificate issued free same day. Confirms new circuit, connection and appliance safety. Valid for landlord records and home insurance.
✓ Always free — £0
Instant quote

Get your exact conversion price — instantly

Select your conversion type and see your fixed price. No callbacks. No waiting.

Gas to electric conversion — London
Select your conversion type
What do you need?
Gas to electric cooker conversionGas disconnection + new circuit + electric cooker — one visit
£200
Gas to induction cooker conversionGas disconnection + new circuit + induction cooker — one visit
£200
Gas to electric range cooker conversionIncludes 45-amp circuit — for range cookers over 7.2kW
£225
Old gas cooker removal add-onRemoval + disposal — add to any conversion
+£25
Your fixed price — London
£0
No hidden charges · Free electrical certificate · No call-out fee
How it works

Gas to electric cooker conversion — step by step in London

Everything done in one visit — 2 to 3 hours. Price confirmed at booking.

1
WhatsApp to book
Free — no call-out fee
Send us your London postcode, current gas cooker details and new electric cooker make and model. We confirm your £200 fixed price immediately. Tell us if you need old cooker removal (£25 add-on) so we allow the correct visit time.
2
Gas Safe disconnection
Included in £200
Our Gas Safe registered engineer safely disconnects your existing gas cooker from the gas supply. The bayonet fitting or gas pipe at the wall is securely capped. A Gas Safe disconnection record is provided. Your boiler and all other gas appliances remain completely unaffected.
3
Old cooker removed (if booked)
£25 add-on
If old cooker removal has been booked, your old gas cooker is removed from the property and taken away for disposal. Kitchen is left clean before the new circuit and cooker installation begins.
4
New 32-amp cooker circuit installed
Included in £200
Our Part P certified electrician installs a new dedicated 32-amp cooker circuit from your consumer unit (fuse board) to the cooker location. Cable is concealed where possible. Required in virtually all London properties switching from gas to electric for the first time.
5
New electric cooker installed and tested
Included in £200
New electric cooker connected to the new circuit, levelled and positioned correctly. All hotplate elements, oven elements, grill and controls tested and confirmed fully working. Anti-tip bracket fitted where required.
6
Certificates issued — same day
Free — always included
Free electrical safety certificate issued same day confirming new circuit installation and Part P compliance. Gas Safe disconnection record also provided. Both valid for landlord compliance records and home insurance documentation.
Safety checks

What our engineers check on every gas to electric conversion in London

All included in the £200 fixed price. Every check completed on every conversion.

🔥
Gas supply fully capped
Gas pipe or bayonet fitting at cooker location confirmed securely capped — zero gas escape possible after disconnection.
📊
Consumer unit assessed
Fuse board checked for available capacity and correct RCD protection before new circuit is added.
🔗
Circuit amperage correct
New circuit confirmed at correct amperage for the specific cooker being installed — 32-amp for standard, 45-amp for large range cookers.
🛡️
RCD protection confirmed
New cooker circuit confirmed protected by RCD at consumer unit — required for kitchen circuits under current UK wiring regulations.
🔌
Connection terminals checked
All terminal connections made to manufacturer specification. Earth continuity confirmed. No loose connections.
🌡️
All elements tested
Every hotplate element, oven element and grill tested and confirmed working on completion.
📐
Cooker levelled
Cooker levelled front-to-back and side-to-side. Adjustable feet set correctly. Positioned correctly in kitchen.
📊
Insulation resistance test
Insulation resistance measured on new circuit to confirm wiring integrity — standard electrical safety test.
📋
Certificates issued
Electrical safety certificate and Gas Safe disconnection record both issued free same day.
🔶
What happens to the gas pipe after conversion?
The gas pipe or bayonet fitting at the cooker location is safely capped and sealed by our Gas Safe engineer. It does not need to be removed — it can remain in place behind the new electric cooker. Your gas supply to all other appliances (boiler, gas hob if separate, gas fire) remains completely unaffected.
⚠️
Smell gas during or after conversion? Call 0800 111 999 immediately.
If you smell gas at any point, turn off the gas at the meter, open windows and leave the property. Call the National Gas Emergency Service 0800 111 999 — free, 24 hours. Do not use any electrical switches. Contact us only once declared safe.
Why choose us

Trusted gas to electric conversion across London

Gas Safe + Part P certified. One visit. £200 fixed. Same day. All London areas.

01
One visit — everything
Gas Safe disconnection + new circuit + electric installation. All in one visit. No need to book separate engineers on different days.
02
Gas Safe + Part P
Our team covers both gas disconnection and certified electrical installation — legally compliant across all London postcodes.
03
£200 fixed price
No call-out fee. No hidden charges. Price confirmed at booking — exactly what you pay. No surprises on the day.
04
Same day London
WhatsApp before noon — same day gas to electric conversion confirmed fast across all London postcodes.
Coverage

Gas to electric conversion — all London areas covered

Fixed £200 price across every London postcode. No area surcharge. No call-out fee.

North London
South London
East London
West London
Chelsea SW3
Fulham SW6
Kensington W8
Hackney E8
Islington N1
Camden NW1
Wandsworth SW18
Southwark SE1
Lewisham SE13
Greenwich SE10
Tower Hamlets E1
Newham E6
Haringey N22
Lambeth SW2
Croydon CR0
Bromley BR1
Ealing W5
Brent HA9
Barnet EN5
Enfield EN1
Clapham SW4
Brixton SW9
Peckham SE15
Shoreditch E1
Dalston N16
Stratford E15
Wood Green N22
Wimbledon SW19
FAQ

Gas to electric cooker conversion London — every question answered

How much does gas to electric cooker conversion cost in London? +
Gas to electric cooker conversion in London costs £200 fixed price. This includes Gas Safe disconnection of your existing gas cooker, installation of a new dedicated 32-amp cooker circuit from the fuse board, electric cooker connection and testing, and a free electrical safety certificate — all in one visit. Old gas cooker removal is a separate £25 add-on. Electric range cooker conversion requiring a 45-amp circuit costs £225. No call-out fee.
Do I need a new cooker circuit when switching from gas to electric in London? +
Yes — in almost all cases. The vast majority of London properties that have only had a gas cooker will not have an existing electric cooker circuit. A new dedicated 32-amp cooker circuit must be installed from the consumer unit to the cooker location. This is included in the £200 conversion price — no extra charge.
What happens to the gas pipe when switching to electric in London? +
Our Gas Safe engineer safely caps the gas pipe or bayonet fitting at the cooker location. It is sealed so no gas can escape. The capped pipe does not need to be removed — it can stay in place behind the new electric cooker. Your boiler, any separate gas hob and all other gas appliances are completely unaffected.
Can you switch from gas to induction in London? +
Yes. We carry out gas to induction conversions across all London areas at the same £200 fixed price. Induction cookers require the same 32-amp circuit as conventional electric cookers. Gas disconnection, new circuit and induction cooker installation — all in one visit.
Is a Gas Safe engineer needed to disconnect the gas cooker? +
Yes. Under the Gas Safety (Installation and Use) Regulations 1998, gas cooker disconnection must be carried out by a Gas Safe registered engineer. Our team is Gas Safe registered — covering this legally at the same time as the electrical installation. No need to book a separate gas engineer.
Is old gas cooker removal included in the £200 price? +
No. Physical removal and disposal of the old gas cooker is a separate £25 add-on. The £200 includes disconnection and all installation work. Book both for £225 total — tell us when you WhatsApp.
Is an electrical safety certificate included? +
Yes. A free electrical safety certificate is included with every gas to electric conversion in London. Issued same day. Confirms Part P compliance, correct circuit installation and appliance safety. Valid for landlord electrical safety records and home insurance.
Can I get same day gas to electric conversion in London? +
Yes. Same day conversion is available across all London postcodes subject to engineer availability. WhatsApp +44 7912 100949 before noon with your postcode and cooker details and we confirm same day availability immediately.
How long does gas to electric conversion take in London? +
A complete gas to electric cooker conversion in London takes 2 to 3 hours in one visit — covering gas disconnection, new circuit installation, electric cooker connection and certificate issuance. If old cooker removal is booked, allow 2.5 to 3.5 hours.
Does gas to electric conversion affect the rest of my gas supply? +
No. Only the gas supply to the cooker location is capped. Your boiler, any separate gas hob, gas fire and all other gas appliances in your London property remain completely unaffected.
Related services

More installation services in London

Book gas to electric cooker conversion in London — £200 fixed

Gas disconnection + new circuit + electric installation · One visit · Free certificate · Old cooker removal £25 · Same day available